Manufacturers and suppliers of Air compressor model for engineering labs worldwide.
Air compressor model....
Manufacturers and suppliers of Air Compressor Test Unit for engineering labs worldwide.
Air Compressor Test Unit....
Manufacturers and suppliers of Air Compressor Test Unit for engineering labs worldwide.
Air Compressor Test Unit....
Manufacturers and suppliers of Air Compressor Test Unit for engineering labs worldwide.
The experimental unit contains all the essential components of a compressor system. The compressor to be tested is a single-stage single-cylinder machine. During the functional test the efficiency of the compressor is investigated against the increasing pressure in the tank over time. The active power of the drive motor is displayed on the switch cabinet. A stopwatch is supplied for time-related measurements. Functional test of a piston compressor - Pressure rise in the tank as function of time - Active power of the drive motor as a function of pressure ....
Manufacturers and suppliers of Air Compressors for engineering labs worldwide.
Air Compressors....
Manufacturers and suppliers of Air Compressors for engineering labs worldwide.
....
Manufacturers and suppliers of Air Conditioner Cooling & Heating Trainer for engineering labs worldwide.
Air Conditioner Cooling & Heating Trainer....
Manufacturers and suppliers of Air Conditioner Module for engineering labs worldwide.
Air Conditioner Module....
Manufacturers and suppliers of Air Conditioning and Ventilation System for engineering labs worldwide.
The experimental set-up represents a real air conditioning and ventilation system. The system capacity is sufficient to climatise a laboratory room. The air conditioning and ventilation system includes a filter element, a fan with controlled speed, a direct evaporator as air cooler, an electric air heater and humidification by steam humidifier. The following functions are possible: heating / cooling and humdifiying / dehumidifying. For this purpose the active components can be run either manually individually or via a central PLC air conditioning controller in automatic operation. The air conditioning controller controls the temperature and air humidity independent of each other. Via time programs, operation is possible dependent on the time of the day or the day of the week, as in reality. Pressure losses can be measured at each section of the duct. All common components, such as filter, air heater / air cooler, outlets, smoke detector, multi-leaf dampers, inspection and fire protection flaps are available and can be explained. A standard connection piece in the air duct enables the connection to an external air duct system to climatise an existing room. The air conditioning and ventilation system consists of three independent system components: main unit, steam humidifier and condensing unit. The connection is performed via hoses. Due to the waste heat the condensing unit should not be placed inside the room to be climatised. The well-structured instructional material sets out the fundamentals and provides a step-by-step guide through the experiments. - practice-oriented principles of air conditioning and ventilation technology - design and servicing of an air conditioning and ventilation system - principles of room air conditioning (h-x diagram) - explanation of components: filter, air heater, air cooler, humidifier, condensing unit, air conditioning controller, flaps, outlets - operation of safety devices - measurement of pressure curve and pressure losses - effect of air cooler, air heater and humidifier on the state of the air at the outlet - investigation of the control behaviour of an automatic air conditioning controller, determination of limiting factors....
Manufacturers and suppliers of Air Conditioning Assemble & Maintenance for engineering labs worldwide.
Air Conditioning Assemble & Maintenance....
Manufacturers and suppliers of Air Conditioning Lab Apparatus for engineering labs worldwide.
Air Conditioning Lab Apparatus....
Manufacturers and suppliers of Air Conditioning Model for engineering labs worldwide.
part of the HSI training system for refrigeration and air conditioning technology. In combination with the base unit the operational model of a full air conditioning system is created. The model is plugged onto the base unit, secured using fasteners and connected with refrigerant hoses to become a complete refrigeration circuit for the air cooler. The room climate is created by the interaction of air temperature, heating temperature and air humidity. The purpose of room air conditioning is to shape the room climate in accordance with the requirements of people or sensitive goods. This model introduces the operation of an air conditioning system and the recirculating air and outer air operating modes. The model includes two air ducts with transparent front. The top air duct serves as climatic chamber whilst the bottom air duct contains the air cooler, two electric air heaters and a steam humidifier. A fan between the two air ducts recirculates the air. A motorised butterfly valve in the top air duct allows a change between outer air and recirculating operation. Dependent on the switching of the two air heaters, the air cooler and the humidifier, the air in the duct system can be cooled, heated, humidified or dehumidified. The individual system components are controlled via the educational software which is included in the scope of delivery of the base unit Temperature and humidity before and after the evaporator and in the climatic chamber are recorded by sensors, digitised and represented dynamically in the educational software. The conditioning of the air can be monitored online in the h-x diagram. - Full air conditioning system and its main components - Heating and cooling in the h-x diagram - Humidifying and dehumidifying in the h-x diagram - Outer air and recirculating operation - Fault simulation....
Manufacturers and suppliers of Air Conditioning System Model for engineering labs worldwide.
Air conditioning technology is a key topic in building services engineering. For this reason air conditioning technology plays an important role during the training of skilled workers and engineers. The clear trainer ET 605 represents a complete air conditioning system with an air duct and a climatic chamber. The main components of the air conditioning system are the air cooler with condensing unit, fan, steam humidifier and air heater. Three motorised ventilation flaps control the air distribution in the air conditioning system. The climatic chamber is equipped with two different heat sources (wet and dry). Temperature and relative humidity are measured at relevant points in the air duct and displayed digitally. For the refrigeration circuit two manometers with integrated temperature scale and a flow meter provide all relevant measurements. is operated manually. A key feature of the air conditioning system is that it is fully ready for various automation solutions. The user can thus focus on this important topic during a lesson. The following solutions are available: - air conditioning system and its components - conditioning room air - mixing different air flows - representation in the h-x diagram for humid air * humidification and dehumidification * heating and cooling - representation of the circuit in the log p-h diagram - effect of a cooling load (dry and wet) - recirculating and outer air operation In conjunction with optional accessories - automation in an air conditioning system....
Manufacturers and suppliers of Air Conditioning System Trainer for engineering labs worldwide.
Air Conditioning System Trainer
....Manufacturers and suppliers of Air Conditioning System with Chamber for engineering labs worldwide.
Comfort is of great importance in the air conditioning of rooms and buildings. The comfort depends on the temperature, the relative humidity and the flow velocity of the air. According to DIN a so-called "comfort zone" has been defined which specifies the values an air conditioning system should achieve. is a full air conditioning system with comprehensive test options. The effect of the air humidity and temperature on the comfort is examined. The system has a climatic chamber designed for test persons to be inside. This allows the trainee to study the effect of different system operating states on his own well-being. The components used, such as radial fan, electric air heater, steam humidifier and water chiller are all used in commercial air conditioning and ventilation technology. A PLC air conditioning controller monitors and controls all functions. In addition to the automatic operation it also enables the manual operation of the system. The well-structured instructional material sets out the fundamentals and provides a step-by-step guide through the experiments. design, operation and operating behaviour of a real air conditioning system - recirculating and outer air operation - changes of state in the h-x diagram for humid air: heating, cooling, humidifying or dehumidifying, mixing - application of the mixing line - comfort studies, limit of comfortable humidity - energy balance in the Sankey diagram - PLC air conditioning controller * humidity control * temperature control * manual or automatic operation....
Manufacturers and suppliers of Air Conditioning System with Climate Chamber for engineering labs worldwide.
Air Conditioning System with Climate Chamber....
Manufacturers and suppliers of Air Conditioning Test Rig for engineering labs worldwide.
Air Conditioning Test Rig....
Manufacturers and suppliers of Air Conditioning Trainer for engineering labs worldwide.
Air Conditioning Trainer....
Manufacturers and suppliers of Air Conditioning Trainer for engineering labs worldwide.
Air Conditioning Trainer....
Manufacturers and suppliers of Air Conditioning Trainer for engineering labs worldwide.
Air Conditioning Trainer....