Computerized Cooling Tower Test Bench
The Computerized Cooling Tower Test Bench examines the main components and principle of a wet cooling tower with forced ventilation.
Water is heated in a tank and transported by a pump to an atomizer.
The atomizer sprays the water to be cooled over the wet deck surface.
The water trickles from the top to the bottom along the wet deck surface whilst air flows from the bottom to the top.
The heat is transferred directly from the water to the air by convection and evaporation.
The evaporated water volume is recorded.
The airflow is generated by a fan and adjusted using a throttle valve.
The cooling column is transparent allowing clear observation of the wet deck surface and the trickling water.
Interchangeable cooling columns enable comparative studies.
The measured values can be read on digital displays.
At the same time, the measured values can also be transmitted directly to a PC via USB.
Software for data acquisition via USB.
All important process parameters are recorded (volumetric air flow rate, temperatures of air and water, air humidity, water flow rate).
The data acquisition software is included.
The changes of state of the air are represented in an h-x diagram.
FEATURES:
Thermodynamic principles of the wet cooling tower
Changes of state of the air in the h-x diagram
Determination of the cooling capacity
Energy balances
Calculation of process parameters, such as maximum cooling distance, cooling zone width etc.
SPECIFICATION:
Cooling column :
Specific surface of the wet deck surface: 110m2/m3
Cross-section: 150x150mm
Volumetric airflow measurement via orifice: Ø 80mm
Heater, adjustable in three stages :
500W
1000W
1500W
Thermostat: switches off at 50°C
Fan :
Power consumption: 250W
Max. Pressure difference: 430Pa
Max. Volumetric flow rate: 13m3/min
Pump :
Max. Head: 70m
Max. Flow rate: 100L/h
Tank for additional water: 4,2L
Measuring ranges :
Differential pressure: 0…1000Pa (air)
Flow rate: 12…360L/h (water)
Temperature: 2x 0…50°C, 3x 0…100°C
Rel. humidity: 10…100%
Required for operation :
230V, 50Hz, 1 phase
230V, 60Hz, 1 phase
Similar items like Computerized Cooling Tower Test Bench you may view
ELAB Engineering is a leading manufacturer, supplier and exporter of computerized cooling tower test bench and a complete range of engineering laboratory and technical training equipment. We supply high-precision, lab-grade instruments in bulk to engineering colleges, universities, technical institutes and industries across 55+ countries — with competitive tender pricing, full export documentation and reliable after-sales support.
As a leading manufacturer, supplier and exporter, we deliver tender-grade quality with documented compliance to institutions, laboratories and training facilities across 55+ countries.
Every unit is manufactured to international quality standards and tested before dispatch, with QC documentation and calibration certificates included.
Established export channels across Africa, Asia and the Middle East, with complete shipping documentation, certificates of origin and customs paperwork.
We offer customisation for tender specifications, OEM branding, voltage variants and bulk institutional orders to match your exact requirement.
Technical consultation before purchase, installation guidance, operator training documentation and responsive after-sales support from our team.
Trusted by institutions, governments and industries worldwide for reliable, tender-documentation-ready supply.
Practical laboratory training & coursework experiments
STEM education & physics / chemistry / biology demos
Process quality, testing & calibration requirements
Clinical lab, diagnostics & pathology applications
Ministry, defence research & PSU lab infrastructure
UNICEF, WHO, UNDP & bilateral aid procurement
Skill development & technical training labs
Direct & sub-contractor tender fulfilment
ELAB Engineering is a recognised manufacturer, supplier and exporter of Computerized Cooling Tower Test Bench. We supply this product across our complete export network — from individual institutional purchases to large-scale tender supply contracts.
All shipments include complete export documentation, customs paperwork & freight handling.
Request a custom quote, full technical datasheet, or place a bulk / tender enquiry. Our specialists respond within 1 business day with pricing, lead time and export documentation.
Common questions from buyers, procurement officers and technical evaluators about ordering, customisation, lead time and documentation.