Religh Bridge
Optional Accessories:
1) Galvalnometer 30-0-30 Division Sensitivity of 2μA/Division
2) Two Dials of 0.1mH & 1mH or Two Dials of 1mH & 10mH or Two
Owen Bridge
Optional Accessories:
1) Fixed Sine wave oscillator.
2) Sensitive Head Phone/Null Detector
3) Two Dials of 0.1mH & 1mH or Two Dials of 1mH & 10mH
Religh Bridge
Optional Accessories:
1) Galvalnometer 30-0-30 Division Sensitivity of 2μA/Division
2) Two Dials of 0.1mH & 1mH or Two Dials of 1mH & 10mH or Two
Hay Bridge
Optional Accessories:
1) Fixed Sine wave oscillator.
2) Sensitive Head Phone/Null Detector
3) Two Dials of 0.1mH & 1mH or Two Dials of 1mH & 10mH
LCR / AC Bridge
Technical Specifications:
Inductance Measurements:
Min : 0.2 microH
Max : 110 H or more
Ranges : 8
Accuracy : + 1% for greater ‘Q’ coils
Capacitance Measurements :
Min : 1 pF
Max : 1110 micro Farad or more
Ranges : 8
Accuracy : + 1%
Resistance Measurements:
Min : 100 milli Ohms
Max : 10 Megohms
Ranges : 8
Accuracy : + 1%
Display : Numeric 3.5 digits
D/QFactor : Available for Fine adjustment Q: 0-30 D : 0 to 3
Excitation : Internal 1KHz + 10% sine wave and DCPower Supply : 220V +/- 10%, 50Hz.
Null Detector Digital
The null detector comprises of a solid state amplifier having output stage with meter indication. The said detector has been designed for use with AC bridges replacement of head phone.
Andersn Bridge
Optional Accessories:
Fixed Frequency Sine Wave Oscillator 1kHz
Unknown Decade Inductance Box
Two Dials of 0.01&0.1 uF
Sensitive Head Phone/Null Detector
Schering Bridge for Capacity Measurement
Optional Accessories:
Fixed Frequency Sine Wave Oscillator 1kHz
Decade Capacitance Box
Sensitive Head Phone/Null Detector
Industrial Kelvin Double Bridge to measure small values Resistance of 0.2 micro ohm to 11ohm
Optional Accessories:
DC Source 0-12VDC/10A
Galvalnometer 30-0-30 Division Sensitivity of 2µA/Division
Conductivity Attachment
Connecting Leads (current carrying capacity 10Amps)
Kelvin Bridge(Student)
Optional Accessories:
DC Source 0-12 VDC/10A
Galvalnometer 30-0-30 Division Sensitivity of 2µA/Division
Conductivity Attachment
Connecting Leads (current carrying capacity 10Amps)
Maxwell Inductance Bridge
Optional Accessories:
1) Fixed Frequency Sine Wave Oscillator
2) Sensitive Head Phone /Null Detector
3) Single Dial of 0.1mH
4) Air Core Inductance in Wooden Box Any value from 0.1mH to 100mH
Weins Bridge (Capacity Measurement)
Optional Accessories:
1) Fixed Frequency Sine Wave Oscillator
2) Sensitive Head Phone /Null Detector
3) Two Dials of 0.01 & 0.1μF
Weins Bridge (Frequency Measurement)
Optional Accessories:
1) 1Hz to 200KHz Function Generator
2) Sensitive Head phone/Null Detector
3) Two Dials of 0.01 & 0.1μF
Wheatstone Bridge (Portable)
Optional Accessories :’Metal Film Resistance of 0.5
Watt in wooden/Bakelite Box
Desauty Bridge
Optional Accessories:
1) Fixed Frequency Sine Wave Oscillator
2) Sensitive Head phone/Null Detector
3) Two Dials of 0.01 & 0.1μF
Carry Foster Slide Wire Bridge
Optional Accessories:
1) Galvalnometer 30-0-30 Division Sensitivity of 2μA/Division
2) Battery Eliminator 2-12 VDC/3 Amps
3) Tapping key |